  • SKU: MPC481M414A
  • UPC: 810512032686
  • MPN: MPC481M414A
Unavailable
Current Stock:Only left:

Frequently Bought Together:

Total: Inc. undefined
Total: Ex. undefined
Description

Tend Industrial Supplies can Supply you MRCOOL 48,000 BTU R410A 14 SEER Single Phase Packaged A/C Only Model MPC481M414A

Our Brand new MRCOOL 48,000 BTU R410A 14 SEER Single Phase Packaged A/C Only Model MPC481M414A is a brand new 4 ton, 208-230 volt, R410-A refrigerant, MRCOOL packaged air conditioning. This air conditioner unit has a seasonal energy efficiency rating of 14 SEER, providing maximum comfort cooling. This unit only provides "cooling" (this is NOT a heat pump).

•Approved for installation in manufactured housing and mobile homes

Multi-Positional Application

Environmentally friendly R410A refrigerant

Insulated to minimize heat loss and reduce sound

Efficient multispeed motor for wide airflow range

Low ambient kits available

Utility connections on right side

One piece base design for strength and stability

Rounded corners for safety and an attractive, clean appearance

Available in 2, 2.5, 3, 3.5, 4, and 5 TON capacities

All units ETL and ETLC approved and AHRI Certified

One piece no leak top design

 

BRAND NAME

MRCOOL

SERIES

Signature Packaged Air Conditioner

MODEL

MPC481M414A

GTIN

00810512032686

UPC

810512032686

UNIT TYPE

Package AC

COUNTRY OF ORIGIN

USA

 

SEER

14

EER

11

CFM

1600

TONNAGE

4

COOLING CAPACITY

45500

VOLTAGE

208-230

PHASE

1

CYCLE

60

MAX FUSE BREAKER

45

MIN CIRCUIT AMPACITY

28.7

COLOR

Gray

COLOR FAMILY

Gray

RATED LOAD

16.9

MAX COVERAGE AREA

2000

REFRIGERANT TYPE

R-410A

REFRIGERANT VOLUME

115

DECIBEL RATING

77

MIN AMBIENT HEAT

0

COMPRESSOR MOTOR TYPE

Single Stage

CONDENSER FAN MOTOR TYPE

ECM

CONDENSER FAN MOTOR HP

1/4

BLOWER MOTOR TYPE

ECM

BLOWER MOTOR HP

3/4

BLOWER MOTOR SPEEDS

Multi-speed

BLOWER MOTOR RPM

850-1640

FILTER TYPE

Replacable

FILTER SIZE

20x20

METERING DEVICE

TXV

AUXILIARY HEATER INCLUDED

No

AUXILIARY HEATER AVAILABLE

Yes

AUXILIARY HEATER SIZES

5kw, 7.5kw, 10kw, 15kw, 20kw

UL RECONIZED

No

UL LISTED

No

ETL LISTED

Yes

ETL CERTIFIED

No

LEED CERTIFIED

No

ASHRAE COMPLIANT

No

ENERGY STAR COMPLIANT

No

ENERGY STAR CERTIFIED

No

AHRI CERTIFIED

Yes

REGISTERED WARRANTY

10-Year Parts Limited Warranty

BASE WARRANTY

5 year base limited parts warranty

HAS BATTERIES

No

CONTAINS ELECTRONICS

Yes

CONTAINS CHEMICALS

Yes

CONTAINS AEROSOL

Yes

CONTAINS COMPRESSED GAS

Yes

PROPOSITION 65 WARNING

Yes

RESTRICTED STATES

No

NET DEPTH

55.27

NET HEIGHT

40.88

NET WIDTH

46.8

NET WEIGHT

411

GROSS DEPTH

48

GROSS HEIGHT

46

GROSS WIDTH

57.5

GROSS WEIGHT

438

FREIGHT CLASS

125

 

BROCHURE

Open

INSTALL MANUAL

Open

SPECS

Open

OWNER MANUAL

Open

WARRANTY DOC

Open

AHRI CERTS

Open

ENERGY GUIDE CERTS

Open

Order MRCOOL 48,000 BTU R410A 14 SEER Single Phase Packaged A/C Only Model MPC481M414A with confidence

Availability: 10 units in stock. Product identity: Brand: MRCOOL · SKU: MPC481M414A.

This hvac equipment page retains the original product information above and adds the buying checks below to help confirm fit before checkout.

Common use cases

  • Residential and light-commercial climate systems
  • HVAC replacement and installation projects
  • Facility maintenance and equipment upgrades

Before you order

  • Confirm capacity, voltage, phase, refrigerant and regional operating requirements.
  • Verify line-set, control, mounting and accessory compatibility.
  • Use a qualified installer and check permit, electrical and commissioning requirements.

Included-items check

The sale includes the product identified on this page and only the accessories expressly stated as included in the original description. Images may show application context; do not assume surrounding equipment or accessories are supplied unless listed.

Frequently asked questions

Can I select HVAC equipment by room size alone?

No. A qualified load calculation should consider climate, insulation, glazing, occupancy and building conditions.

Is professional installation required?

Follow the manufacturer, electrical, refrigerant and local-code requirements; professional installation is normally required.

What accessories should I confirm?

Check the line set, controls, disconnect, mounting components, drain and any model-specific installation kit.

Ready to order? Select the quantity and add MRCOOL 48,000 BTU R410A 14 SEER Single Phase Packaged A/C Only Model MPC481M414A to your cart. If compatibility, delivery timing or included items affect your decision, contact Tend Industrial Supplies before checkout.